Three-in-one check valve

Technical Parameter

Item model number: JLH

Nominal diameter: DN50~1000mm

Nominal pressure: PN1.0~2.5MPa

Operating temperature: 0°C~80°C

Applicable medium: water, sewage


Product Detail

Product Description

JLH three-in-one check valve has three functions: cut-off, non-return and throttling. It is mainly used for the outlet of the pump or other pipelines to prevent the backflow of the liquid, which can effectively prevent the water hammer impact and noise caused by the backflow of the ordinary check valve. It is suitable for water supply and drainage in general buildings, apartments and factories, cold and warm water treatment and boiler condensate water, and on the pump outlet of the secondary water supply pipeline to prevent the backflow of the medium in the pipeline caused by the stop of the pump.


Scope Of Application

The three-in-one check valve is installed on the water supply and drainage of general buildings, apartments and factories, cold and warm water treatment, and boiler condensate water, and on the pump outlet of the secondary water supply pipeline to prevent the medium in the pipeline caused by the stop of the pump. Backflow.


Product Features

1. With one valve, three functions can be successfully completed: non-water hammer check valve, gate valve, balance valve.

2. When the pump stops running, the spring force closes the valve disc first, thus preventing water hammer.

3. By adjusting the opening, the output of the pump can be adjusted.

4. Equipped with an indicator, the opening degree of the valve can be confirmed with eyes.

5. The gasket is made of nitrile rubber, so it will not leak at all and can absorb the impact.

6. The spring is made of stainless steel, so it has strong corrosion resistance.

7. Equipment materials and costs that can save water and reduce installation space.

8. Because the shape and structure are highly streamlined, the pressure drop is very small.

9. Because of its bypass function, it has the function of recovering the water in the pipeline on the outlet side, and supplementary water diversion when a vacuum occurs on the inlet side.

10. Both horizontal pipes and vertical pipes can be installed.


三合一止回阀(图1)

Main External Connection Dimensions

DN

L

H

D

D1

D2




1.0MPa

1.6MPa

2.5MPa

1.0MPa

1.6MPa

2.5MPa

1.0MPa

1.6MPa

2.5MPa

50

205


293

165

165

165

125

125

125

4-18

4-18

4-18

65

215


328

185

185

185

145

145

145

4-18

4-18

8-18

80

250


364

200

200

200

160

160

160

8-18

8-18

8-18

100

320


418

220

220

235

180

180

190

8-18

8-18

8-22

125

365


481

250

250

270

210

210

220

8-18

8-18

8-22

150

415

380

543

285

285

300

240

240

250

8-22

8-22

8-26

200

500

450

673

340

340

360

295

295

310

8-22

12-22

8-26

250

600

540

792

395

405

425

350

355

370

12-22

12-26

12-26

300

680

600

927

445

460

485

400

410

430

12-22

12-26

12-30

350

780

635

957

505

520

555

460

470

490

16-22

16-26

16-33

400

860

700

1188

565

580

620

515

525

550

16-26

16-30

16-36

450

920

780

1218

615

640

670

565

585

600

20-26

20-30

20-36

500

980

810

1256

670

715

730

620

650

660

20-26

20-33

20-36

600

1100

900

1600

780

840


725

770


20-30

20-36


700

1450

980

1750

895

910


840

840


24-30

24-36


800

1650

1120

1900

1015

1025


950

950


24-33

24-39


900

1800

1220

2100

1115



1050



28-33



1000

2000

1320

2400

1230



1160



28-36