Hand (electric) moving butterfly cold air release valve

Technical Parameter

Product model: FS48(948)W

Nominal diameter: DN400~2800mm

Nominal pressure: 0.05~0.25MPa

Applicable temperature: ≤250℃

Drive mode: electric, hydraulic, pneumatic, electro-hydraulic

Applicable medium: air, heating furnace gas, blast furnace gas, converter gas, flue gas, etc.

Body Material: Carbon Steel, Rubber, Chrome Steel

Design standard: API 600, API6D, ASME B16.34, GB/T 12234

Structure length: ASME B16.10, API6D, GB/T 12221

Connection standard: ASME B16.5, ASME B16.47, GB/T 9113, JB/T 79, HG/T 20592

Pressure test: API 598, GB/T 13927, JB/T 9092

Pressure-temperature class: ASME B16.34, GB/T 12224


Product Detail

Product overview

Manual (electric) butterfly type cold air release valve is composed of valve body, butterfly plate, connecting rod, muffler, exhaust duct and other components. Use a manual lever mechanism or an electric device to turn the butterfly plate to open and close the valve, so as to reduce or completely stop the air supply to the blast furnace without stopping the blower, and discharge the excess gas into the atmosphere. The special place in its structure is the electric drive that can be operated remotely. The size of the flap of the vent valve can be moved to easily change the size of the air volume, and the output signal can be reversed through the automatic position on the vent valve. Use the DFP-09 electric operator to display the size of the valve opening. As long as the electric operator is controlled, the required air volume can be achieved. It is suitable for ventilation ducts in building materials, metallurgy, chemical industry, power stations and other industries, as a device for automatic adjustment or remote control of the air volume required by equipment. Under the condition of given air pressure, the required air volume is automatically controlled by the servo amplifier, electric operator, valve position feedback and other devices. The structure is simple and the operation is convenient. In order to improve the linearity of the valve opening, the double-valve structure is adopted.


手(电)动蝶式冷风放散阀(图1)

Main outline and connection size

DN

D1

D

L

b

N-d

H

H1

H2

&

WT (Kg)

Manual

Electric

400

495

540

350

16

16-22

650

380

660

350

205

225

450

550

595

370

16

16-22

700

380

690

350

228

250

500

600

645

400

20

20-22

730

450

720

400

265

300

600

705

755

530

20

20-26

870

525

780

400

403

440

700

810

860

60

24

24-26

1070

600

830

500

650

685

800

920

975

750

24

24-30

1190

700

880

500

850

890

900

1020

1075

750

24

24-30

1510

750

930

600

1100

1140

1000

1120

1175

800

28

28-30

1680

800

1000

600

1380

1430

1200

1320

1375

900

32

32-30

1880

900

1100

700

1880

1930

1400

1520

1575

1000

36

36-30

2110

1050

1250

700

2530

2590